Underground Ventilation Fans High Temperature Wind Tunnel Smoke Fire Exhaust Ventilating Fan

Customization: Available
Material: Stainless Steel
Usage: Coal Mine

Products Details

Basic Info.

Flow Direction
Axial Flow
Pressure
High Pressure
Certification
CE
Model
Ybt-2.2
Voltage
380
Full Wind Pressure PA
1050-380
DC Curair Volumem3/Minrent (a)
55-101
Full Pressure Efficiency%
80
Noisedb(a)
87
Highest Efficiency(%)
315
Continuous
Continuous
Transport Package
Standarad Package
Specification
mm
Trademark
china coal
Origin
China
Production Capacity
100set/Month

Product Description

Introduction of Underground Ventilation Fans High Temperature Wind Tunnel Smoke Fire Exhaust Ventilating Fan

YBT series mine partial axial flow fan is mainly used for press-in local ventilator in coal mines containing gas or coal dust explosion hazard. This product is also suitable for mines in metal mines, chemical mines, tunnels and other application fans. . The temperature of the conveying medium does not exceed 40 ° C, the temperature is not more than 95 ± 3% (25 ° C) and non-corrosive. This series of fans is explosion-proof and the explosion-proof mark is ExdI.zmwm02
 

Working Conditions Of Underground Ventilation Fans High Temperature Wind Tunnel Smoke Fire Exhaust Ventilating Fan

  1. The environment temperature is -15 ° C ~ +40 ° C;
  2. The environment air relative temperature is not more than 90% (at +25 °C);
  3. The altitude does not exceed 1000m;
  4. No strong vibration and corrosive gases, etc.;
  5. Installed in the air inlet tunnel under the coal mine with gas gas explosion hazard.

Parameter Of Underground Ventilation Fans High Temperature Wind Tunnel Smoke Fire Exhaust Ventilating Fan

 
  YBT-2.2 YBT-4 YBT-5.5 YBT-11 YBT-18.5 YBT-22 YBT-30
Air fan Voltage 380 380/660 380/660 380/660 380/660 380/600 380/660
Full wind pressurePa 1050-380 1390-880 1700-800 2250-880 3180-910 3315-950 3690-1100
Air volumem3/min 55-101 85-164 90-180 130-240 195-330 240-380 250-455
Full pressure efficiency% 80 80 81.5 80 80 80 80
noisedB(A) 87 90 89 91 95 95 95
Diameter of impellermm 315 400 400 500 560 560 630
continuous continuous continuous continuous continuous continuous continuous continuous

Photos Of Underground Ventilation Fans High Temperature Wind Tunnel Smoke Fire Exhaust Ventilating Fan 

Underground Ventilation Fans High Temperature Wind Tunnel Smoke Fire Exhaust Ventilating FanUnderground Ventilation Fans High Temperature Wind Tunnel Smoke Fire Exhaust Ventilating FanUnderground Ventilation Fans High Temperature Wind Tunnel Smoke Fire Exhaust Ventilating FanUnderground Ventilation Fans High Temperature Wind Tunnel Smoke Fire Exhaust Ventilating FanUnderground Ventilation Fans High Temperature Wind Tunnel Smoke Fire Exhaust Ventilating FanUnderground Ventilation Fans High Temperature Wind Tunnel Smoke Fire Exhaust Ventilating FanUnderground Ventilation Fans High Temperature Wind Tunnel Smoke Fire Exhaust Ventilating FanUnderground Ventilation Fans High Temperature Wind Tunnel Smoke Fire Exhaust Ventilating FanUnderground Ventilation Fans High Temperature Wind Tunnel Smoke Fire Exhaust Ventilating FanUnderground Ventilation Fans High Temperature Wind Tunnel Smoke Fire Exhaust Ventilating FanUnderground Ventilation Fans High Temperature Wind Tunnel Smoke Fire Exhaust Ventilating Fan

Contact us