- Overview
- Application
- Company Profile
- Packaging & Shipping
- FAQ
Basic Info.
Product Description
XH-BF-17 centrifugal exhaust fan is to burn a variety of coal and with a smoke and dust removal device 1 ton / h -20 tons / h supporting the design of industrial boilers, where the intake conditions are comparable, similar performance can be used , But the maximum temperature shall not exceed 250 ºC, in the induced draft fan must be installed before the dust removal efficiency of not less than 85% of the dust removal device to reduce the smoke into the fan dust content, improve fan life.
Ventilator conveyor medium is the air, the maximum temperature shall not exceed 80 ºC; induced draft fan for the media is flue gas, the maximum temperature shall not exceed
250 ºC.
Dust removal device must be installed in the front of fan to minimize the amount of dust into the fan. According to the usage of general power plants, the efficiency of equipped dust collector shall not be less than 85%.

Notes:
When you want to use this series of fans to transport the gas that is flammable, explosive, corrosive or temperature over 80 ºC, we are designed and manufactured for you before your order.

Performance Curve&Parameter
Machine NO.
Induced draft mechanism into a single inhalation, machine number has 6: 4,5,6.3,8,10,12.5
As this series Centrifugal exhaust fans have many different machine No and parameters, so if the following spes can't meet your demand,please contact our sales manager to get introduction book or catalog. Thanks for your patience!
XH-BF-17№4C Performance Sheet
Speed (r/min) | Volume m3/h | Total Pressure Pa | Internal Efficiency % | Internal Power kw | Required Power kw | Motor |
Power kw | ||||||
3550 | 2932 3374 3807 4254 4686 5143 5564 | 2221 2254 2173 2068 1914 1726 1501 | 70 74.1 77.2 78.7 77.7 74.4 70 | 2.57 2.83 2.95 3.08 3.18 3.30 3.30 | 3.52 3.87 4.04 4.22 4.36 4.51 4.52 | 5.5 |
3150 | 2602 2993 3378 3775 4158 4563 4937 | 1746 1772 1708 1626 1505 1357 1180 | 70 74.1 77.2 78.7 77.7 74.4 70 | 1.80 1.97 2.06 2.15 2.22 2.30 2.31 | 2.46 2.70 2.82 2.95 3.04 3.15 3.16 | 4 |
2800 | 2313 2661 3003 3355 3696 4056 4388 | 1377 1398 1348 1283 1188 1071 932 | 70 74.1 77.2 78.7 77.7 74.4 70 | 1.26 1.39 1.45 1.51 1.56 1.62 1.62 | 1.73 1.90 1.98 2.07 2.14 2.21 2.22 | 3 |
2500 | 2065 2376 2681 2996 3300 3622 3918 | 1097 1113 1073 1022 946 853 742 | 70 74.1 77.2 78.7 77.7 74.4 70 | 0.90 0.99 1.03 1.08 1.11 1.15 1.53 | 1.23 1.35 1.41 1.47 1.52 1.57 1.58 | 2.2 |
XH-BF-17 №5C Performance Sheet
Speed r/min | Volume m3/h | Total Pressure Pa | Internal Efficiency % | Internal Power kw | Required Power kw | Motor |
Power kw | ||||||
3150 | 5304 6062 6820 7578 8336 9093 9851 | 2819 2793 2737 2592 2406 2175 1913 | 72 75.9 78.7 80 79.1 76 72 | 5.71 6.13 6.52 6.76 6.98 7.17 7.22 | 7.81 8.39 8.92 9.25 9.55 9.81 9.88 | 11 |
2800 | 4715 5389 6062 6736 7409 8083 8757 | 2223 2203 2158 2044 1898 1716 1509 | 72 75.9 78.7 80 79.1 76 72 | 4.01 4.31 4.58 4.75 4.90 5.03 5.07 | 5.49 5.90 6.27 6.50 6.71 6.89 6.94 | 7.5 |
2500 | 4210 4811 5413 6014 6616 7217 7818 | 1769 1753 1718 1627 1511 1366 1202 | 72 75.9 78.7 80 79.1 76 72 | 2.85 3.07 3.26 3.38 3.49 3.58 3.61 | 3.90 4.20 4.46 4.62 4.77 4.90 4.94 | 5.5 |
2240 | 3772 4311 4850 5389 5928 6466 7005 | 1419 1406 1377 1305 1212 1096 964 | 72 75.9 78.7 80 79.1 76 72 | 2.05 2.21 2.34 2.43 2.51 2.58 2.60 | 2.81 3.02 3.21 3.33 3.43 3.53 3.55 | 4 |
For more differeent machine No and specification,please check other XH-CF-17 series.Please be forgiven if there is any inconveniences occurred.
Ordering instructions
To make the proper fan selection, you must consider the following system conditions the fan will be subjected to:
1. What is the required airflow?
This is rated in cubic feet of air per minute (CFM) or, in metric equivalent, it is rated in cubic meters of air per hour (M³/Hr).
2. What is the static pressure through the complete system?
This is rated in static pressure water gauge (SP) or, in metric equivalent, it is rated in Pascal's (Pa).
3. What is the ambient air temperature outside the fan?
4. What will be the airflow conditions through the fan?
B. Dry or wet (moisture laden) air?
C. Temperature of air?
5. What is the altitude the fan will be operating in?
6. Will the air stream, inside the fan, contain anything that could be explosive or flammable?
7. Will the general location the fan will be operating in contain any type of explosive or flammable material or liquid?
When the exiting machine number, rotation, the wind angle and transmission mode can not meet the needs of users, we can design according to the fan similar theory and the user's specific parameters requirements.
Technical Support Service
When using our centrifugal exhaust fans, If any problems on installation,operation,maintainance..and so on, please contact our sale manager directly or leave a message on our website, we will call you in the first time.
Detailed Performance Catalog
Contact our sales manager to get a list of available fan sizes and to view detailed performance curves for each fan KuangFeng builds.
The company was founded in 1993 and, after decades of development, has been able to produce over 200 series and over 1200 products, with an annual production capacity of 20 million. The products are widely used in industries such as boilers, workshops, mines, textiles, oil fields, chemicals, kilns, metallurgy, power plants, cement plants, alumina, electrolytic aluminum, building materials, etc. The mining fans, axial flow fans, cotton opening fans, and material conveying fans produced have been inspected by customs and commodity inspection departments and exported to Southeast Asia, Pakistan, Algeria, Kazakhstan, and other countries, deeply favored in the international market.

1. 24*7 hours online service
2.Live video for the workshop by WhatsApp wechat or youtube.
3.Production according to your drawing(2D/3D)
4.High standard quality control- Testing video/Testing report available
5.Welding / Materials testing report available
6.Surface Treatment: automatic electrostatic powder coating ( ie spray) or spray paint.
7.Corrosion protection and rust removal treatment
A: Air flow rate(m3/h), Total pressure(Pa) or Static pressure(Pa), Inlet temperature(°C), Voltage and frequency on the working site.
2. Q:What is your delivery time?
A:15-35workdays, depending on the model of the fan.
3.Q:Are you manufacturer or trading company?
A:We are the professional manufacturer of centrifugal fans , over 30 years production experience and sales experience.
4.Q:What's your MOQ?
A:The MOQ is 1set,but larger quantity, lower price.
5.Q: What's your warranty?
A: 12 months after arrival of the goods on site.
6.Q:How do you control the product's quality?
A:All the products have quality testing and dynamic balance before delivery.